Lifestyle lenses

DigiMax

Supporting digital activities

Explore design and specifications
THE DESIGN AT A GLANCE

Anti-Fatigue design with near-power steps of 0.50, 0.75 and 0.90 D in the product sheet; selection depends on prescription and professional assessment.

Durabon catalogue ↗
DESIGN / PURPOSE

Application and design rationale

Limited support in the lower lens

Its three steps of 0.50, 0.75 and 0.90 D distinguish this model from ReadMax and RestMax. Its dedicated catalogue table confirms personalisation.

Design identity
Design identifierDescription
CategoryMid-range anti-fatigue lens / single-vision alternative for digital activities
Design typeFull Field Progressive
TECHNICAL PROFILE

Technical specifications

Orderable options depend on prescription, material and current product availability.

DigiMax technical specifications
Technical parameterValue / status
Product classMarket SegmentMedium Anti-Fatigue
Design typeDesign TypeFull Field Progressive
Available materialsAllowed MaterialsAll materials
Pre-calibrationPrecalibrationYes
PersonalisationPersonalizationYes (full personalisation)
Prism reference pointPrism Ref. Point (PRP)Geometrical Center
Distance reference pointDistance Ref. Point (DRP)Same as PRP
Fitting reference pointLayout Reference Point (LRP)Same as PRP
InsetInset0–4 mm (Core Inset)
Power-correction stepsPower Correction0.50 – 0.75 – 0.90 dpt (in the text 0,90)
Cylinder rangeCylinder Range−8.00 to +8.00 D
NRP / corridor lengthNRP / Corridor LengthNot stated in the official table
PRP decentration range0 to 15 mm
Specified indices and optionsRefractive indices 1.50, 1.53, 1.60, 1.67 and 1.74; confirm final availability when ordering.
DESIGN / ENGINEERING

Design mechanism and features

Three steps of near-work support

DigiMax is described as Medium Anti-Fatigue and Full Field Progressive. Power Correction values are 0.50, 0.75 and 0.90 D, selected from prescription/accommodation assessment rather than age alone.

Technology and reference-point positioning

The document identifies DuraBase / Nominal Power and Core Inset. DRP and LRP both coincide with PRP. The dedicated table omits NRP/corridor length; 14 mm from a comparison table is not treated as definitive.

Personalisation

DigiMax's dedicated table states Personalization: Yes; the RestMax/YoungMax comparison table says No. This page and its comparisons follow the dedicated DigiMax table.

COMPARE / DESIGN

Compare related designs

Comparing design features
ComponentDigiMaxReadMax
ClassMedium Anti-FatigueHigh-end Anti-Fatigue
Boost steps (D)0.50, 0.75, 0.900.25, 0.50, 0.75, 1.00, 1.25, 1.50
TechnologyDuraBase / Core InsetDuraTrace / DuraTrack / Core Inset
PersonalisationYesYes
DRPEqual to PRP+10 mm
LRPEqual to PRP+4 mm
NRPNot stated in the dedicated table18 mm
ENGINEERED FOR VISION

Technologies in this design

DuraBase
Nominal-power calculations; also described as Nominal Power in the sources.
Core Inset
Standard automatic inset for near-zone positioning, as specified in the product table.
POSITION OF WEAR

Measure before manufacture

Required parameters vary by design and must be recorded by a professional.

Monocular PD
Each eye's pupillary distance is recorded separately to align horizontal lens positioning with the visual axis.
Fitting Height
Fitting height is recorded on the adjusted frame in the natural position of wear; the required near zone must also fit within the frame.
BVD
Distance from the rear lens surface to the corneal apex; relevant to power-compensation calculations in personalised models.
Pantoscopic Angle
The frame's vertical tilt in the position of wear must be measured; example values are not substitutes for measurement.
Wrap Angle
The horizontal curvature of the frame relative to the face, describing lens positioning.
Box A
Horizontal width of the frame opening in the boxing system.
Box B
Vertical height of the frame opening in the boxing system.
DBL
Distance between the two lens boxes at the frame bridge.
ED
Effective diameter: twice the greatest distance from the boxing centre to the lens-shape edge, used for blank selection and edging calculations.

Design-specific inputs

  • Core Inset (0–4 mm): calculated horizontal shift of the lower lens according to physiological convergence.
Monocular pupillary distance

Monocular pupillary distance

For aligning the lens centre with each eye's visual axis.

Fitting height

Fitting height

Vertical pupil position relative to the frame in the position of wear.

Back vertex distance

Back vertex distance

One of the inputs describing the actual position of wear.

These are basic fitting parameters; additional inputs and the level of personalisation are specified for each model.

Complete parameter guide ↖
SOURCE / CATALOGUE 2026

Original details in the catalogue

Catalogue prices relate to the published edition; enquire for current prices and prescription availability.

View English catalogue ↗
View the original catalogue pageCatalogue page DigiMax